12 | BEKO TECHNOLOGIES GMBH
7. Electrical supply
7.1 Connection
1. The dryer is designed to operate on either an AC or DC supply voltage.
Ensure only one power source is connected at any one time, and it is connected to
the correct socket. Cover supplied must be fitted to the power connection not in use.
2. The power supply is to the DIN plug.
3. The dryer is double insulated
therefore no earth is required.
4. Suitable external fuse connection
must be provided.
5. The cable selection must suit
local installation regulations and
be appropriate to power consumption.
Supply Amp
12 VDC 0.8
24 VDC 0.4
100 VAC 0.16
115 VAC 0.14
230 VAC 0.07
240 VAC 0.067
No connection must be made
to earth terminal
Figure 6.1
Vue de la page 11