- 9 -
<Caution>
(1) The power of the signal generator should be turned on before turning on the power of DC power supply.
(2) The voltage of DC power supply , in standard of Module input voltage, should be preset as below.
Vcc: 5V, Va: 65V, Vs: 185V
(3) The power of power supply must turned on by this sequence. Reverse direction When turning off.
* Module on : 5V
(
Va
(
Vs, Module off: Vs
(
Va
(
5V
(4) Signal generator should be selected with 852*480(WVGA) mode
185 1.0
voltage
65
0.1
voltage
5 1.5
voltage
Y - SUS
Z
-
SUS
E/ X Tube
X rig ht
X Lef t
CONTROLLER
Power
Signal Generator(VG-825)
DC Power Supply for 5V
DC Power Supply for Va
DC Power Supply for Vs
(Fig. 1) Connection diagram of measuring instrument